Attention: Before adjusting the height, heat both pelletizer and extruder to operating temperature!
Process:
- Measure height of extruder (with tape measure)
- Measure height of EUP (with tape measure)
- Adjust height of EUP to extruder (height of EUP is adjusted by nuts/threaded rods on lower frame)
- Check height of EUP
- Check if EUP is horizontal
- Fix height of EUP (nuts on lower frame)
- Final check to see if the set height matches the layout
- Measure distance between adapter and extruder with feeler gauge
Next step: Connect EUP to extruder (C-clamp)
Previous step: Overview start-up
Start-Up Part 1: Preperation
progress
14%
Start-Up
progress
5%