Attention: Before adjusting the height, heat both pelletizer and extruder to operating temperature!
Process:
- Measure height of extruder (with tape measure)
 - Measure height of EUP (with tape measure)
 - Adjust height of EUP to extruder (height of EUP is adjusted by nuts/threaded rods on lower frame)
 - Check height of EUP
 - Check if EUP is horizontal
 - Fix height of EUP (nuts on lower frame)
 - Final check to see if the set height matches the layout
 - Measure distance between adapter and extruder with feeler gauge
 
Next step: Connect EUP to extruder (C-clamp)
Previous step: Overview start-up
								