Grind knife carrier

Process:

  1. Check that water tank is filled with water
  2. Remove knife carrier from EUP
  3. Use a sharpie and mark edges of knives
  4. Mount knife carrier again
  5. Close cutting chamber
  6. Switch to “manual mode”
  7. Start grinding process (press “manual downstream Start”, then press “manual pelletizer Start”)
  8. Let EUP run for 2 minutes
  9. Stop grinding process (press “manual pelletizer Stop”, then press press “manual downstream Start”)
  10. Wait until water has drained from inspection glass
  11. Open cutting chamber
  12. Remove knife carrier from EUP
  13. Check that all knives are grounded
  14. If not all knives are grounded correctly, repeat grinding process for 1 minute

Next step: (First) Production of pellets

Previous step: Check rotation direction of motors

Start-Up Part 2: Initial Operation
progress 100%
Start-Up
progress 63%