Process:
- Fill water into collection container (enough that bottom of container is covered)
- Push collection container underneath diverter valve
- Open safety switch and splash guard
- Check if extruder produces a constant stream of polymer melt
- Turn on automatic mode
- Close splash guard
- Close safety switch
- Check movement of diverter valve
- Check that die plate is rinsed
- Open safety switch
- Open splash guard
- Check that polymer melt streams into collection container
- Clean die plate with a scraper
- Check that all nozzles of die plate are open
- Spray anti-adhesive spray (silicone spray) on die plate, knife carrier and knives
- Close cutting chamber (EUP starts automatically)
- Check inspection glass for water and pellets
- Check pellets at outlet
Next step: Start and Stop in automatic mode
Previous step: Grind knife carrier
Start-Up Part 3: Production
progress
20%
Start-Up
progress
68%